LOGO

Selector Configurator DANFOSS VLT HVAC Drive FC102 drive

Twitter
Home
Exit
FC102
FC102
VLT® HVAC Drive FC 102 Perfect match for: HVAC applications Danfoss VLT® HVAC Drive is dedicated to ventilation, heating, and refrigeration applications. With a wide range of powerful standard and optional features, the VLT® HVAC Drive provides the lowest overall cost of ownership. Product Range 200-240 V ..... 1.1 kW - 45 kW 380-480 V ..... 1.1 kW-1000kW 525-600 V ..... 1.1 kW - 90 kW 525-690 V ..... 11 kW - 1.4 MW
3AC 200V - 240V 50/60 Hz
Order Nr.
Power.-kW
Curr. A
Size
IP
1.1
6.6
A2
20
1.1
6.6
A2
21
1.1
6.6
A5
55
1.1
6.6
A5
56
1.5
7.5
A2
20
1.5
7.5
A2
21
1.5
7.5
A5
55
1.5
7.5
A5
56
2.2
10.6
A2
20
2.2
10.6
A2
21
2.2
10.6
A5
55
2.2
10.6
A5
56
3.0
12.5
A3
20
3.0
12.5
A3
21
3.0
12.5
A5
55
3.0
12.5
A5
56
3.7
16.7
A3
20
3.7
16.7
A3
21
3.7
16.7
A5
55
3.7
16.7
A5
56
5.5
24.2
B3
20
5.5
24.2
B1
21
5.5
24.2
B1
55
5.5
24.2
B1
56
7.5
30.8
B3
20
7.5
30.8
B1
21
7.5
30.8
B1
55
7.5
30.8
B1
56
11.0
46.2
B3
20
11.0
46.2
B1
21
11.0
46.2
B1
55
11.0
46.2
B1
56
15.0
59.4
B4
20
15.0
59.4
B2
21
15.0
59.4
B2
55
15.0
59.4
B2
56
18.0
74.8
B4
20
18.0
74.8
C1
21
18.0
74.8
C1
55
18.0
74.8
C1
56
22.0
88.0
C3
20
22.0
88.0
C1
21
22.0
88.0
C1
55
22.0
88.0
C1
56
30.0
115.0
C3
20
30.0
115.0
C1
21
30.0
115.0
C1
55
30.0
115.0
C1
56
37.0
143.0
C4
20
37.0
143.0
C2
21
37.0
143.0
C2
55
37.0
143.0
C2
56
3AC 380V - 480V 50/60 Hz
Order Nr.
Power.-kW
Curr. A
Size
IP
1.1
3.0
A2
20
1.1
3.0
A2
21
1.1
3.0
A5
55
1.1
3.0
A5
66
1.5
4.1
A2
20
1.5
4.1
A2
21
1.5
4.1
A5
55
1.5
4.1
A5
66
2.2
5.6
A2
20
2.2
5.6
A2
21
2.2
5.6
A5
55
2.2
5.6
A5
66
3.0
7.2
A2
20
3.0
7.2
A2
21
3.0
7.2
A5
55
3.0
7.2
A5
66
4.0
10.0
A2
20
4.0
10.0
A2
21
4.0
10.0
A5
55
4.0
10.0
A5
66
5.5
13.0
A3
20
5.5
13.0
A3
21
5.5
13.0
A5
55
5.5
13.0
A5
66
7.5
16.0
A3
20
7.5
16.0
A3
21
7.5
16.0
A5
55
7.5
16.0
A5
66
11.0
24.0
B3
20
11.0
24.0
B1
21
11.0
24.0
B1
55
11.0
24.0
B1
66
15.0
32.0
B3
20
15.0
32.0
B1
21
15.0
32.0
B1
55
15.0
32.0
B1
66
18.0
37.5
B3
20
18.0
37.5
B1
21
18.0
37.5
B1
55
18.0
37.5
B1
66
22.0
44.0
B4
20
22.0
44.0
B2
21
22.0
44.0
B2
55
22.0
44.0
B2
66
30.0
61.0
B4
20
30.0
61.0
B2
21
30.0
61.0
B2
55
30.0
61.0
B2
66
37.0
73.0
B4
20
37.0
73.0
C1
21
37.0
73.0
C1
55
37.0
73.0
C1
66
45.0
90.0
C3
20
45.0
90.0
C1
21
45.0
90.0
C1
55
45.0
90.0
C1
66
55.0
106.0
C3
20
55.0
106.0
C1
21
55.0
106.0
C1
55
55.0
106.0
C1
66
75.0
147.0
C4
20
75.0
147.0
C2
21
75.0
147.0
C2
55
75.0
147.0
C2
66
90.0
177.0
C4
20
90.0
177.0
C2
21
90.0
177.0
C2
55
90.0
177.0
C2
66
3AC 525V - 600V 50/60 Hz
Order Nr.
Power.-kW
Curr. A
Size
IP
1.1
2.6
A3
20
1.1
2.6
A3
21
1.1
2.6
A5
55
1.1
2.6
A5
66
1.5
2.9
A3
20
1.5
2.9
A3
21
1.5
2.9
A5
55
1.5
2.9
A5
66
2.2
4.1
A3
20
2.2
4.1
A3
21
2.2
4.1
A5
55
2.2
4.1
A5
66
3.0
5.2
A3
20
3.0
5.2
A3
21
3.0
5.2
A5
55
3.0
5.2
A5
66
4.0
6.4
A3
20
4.0
6.4
A3
21
4.0
6.4
A5
55
4.0
6.4
A5
66
5.5
9.5
A3
20
5.5
9.5
A3
21
5.5
9.5
A5
55
5.5
9.5
A5
66
7.5
11.5
A3
20
7.5
11.5
A3
21
7.5
11.5
A5
55
7.5
11.5
A5
66
11.0
19.0
B3
20
11.0
19.0
B1
21
11.0
19.0
B1
55
11.0
19.0
B1
66
15.0
23.0
B3
20
15.0
23.0
B1
21
15.0
23.0
B1
55
15.0
23.0
B1
66
18.0
28.0
B3
20
18.0
28.0
B1
21
18.0
28.0
B1
55
18.0
28.0
B1
66
22.0
36.0
B4
20
22.0
36.0
B2
21
22.0
36.0
B2
55
22.0
36.0
B2
66
30.0
43.0
B4
20
30.0
43.0
B2
21
30.0
43.0
B2
55
30.0
43.0
B2
66
37.0
54.0
B4
20
37.0
54.0
C1
21
37.0
54.0
C1
55
37.0
54.0
C1
66
45.0
65.0
C3
20
45.0
65.0
C1
21
45.0
65.0
C1
55
45.0
65.0
C1
66
55.0
87.0
C3
20
55.0
87.0
C1
21
55.0
87.0
C1
55
55.0
87.0
C1
66
75.0
105.0
C4
20
75.0
105.0
C2
21
75.0
105.0
C2
55
75.0
105.0
C2
66
90.0
137.0
C4
20
90.0
137.0
C2
21
90.0
137.0
C2
55
90.0
137.0
C2
66
VLT HVAC Drive FC102. Low-voltage inverter. Supply voltage 3AC 200-240 V. Power 1,1 kw. Output current 6,6 A, . Frame size A2. IP 20
VLT HVAC Drive FC102. Low-voltage inverter. Supply voltage 3AC 200-240 V. Power 1,5 kw. Output current 7,5 A, . Frame size A2. IP 20
VLT HVAC Drive FC102. Low-voltage inverter. Supply voltage 3AC 200-240 V. Power 2,2 kw. Output current 10,6 A, . Frame size A2. IP 20
VLT HVAC Drive FC102. Low-voltage inverter. Supply voltage 3AC 200-240 V. Power 3 kw. Output current 12,5 A, . Frame size A3. IP 20
VLT HVAC Drive FC102. Low-voltage inverter. Supply voltage 3AC 200-240 V. Power 3,7 kw. Output current 16,7 A, . Frame size A3. IP 20
VLT HVAC Drive FC102. Low-voltage inverter. Supply voltage 3AC 200-240 V. Power 5,5 kw. Output current 24,2 A, . Frame size B3. IP 20
VLT HVAC Drive FC102. Low-voltage inverter. Supply voltage 3AC 200-240 V. Power 7,5 kw. Output current 30,8 A, . Frame size B3. IP 20
VLT HVAC Drive FC102. Low-voltage inverter. Supply voltage 3AC 200-240 V. Power 11 kw. Output current 46,2 A, . Frame size B3. IP 20
VLT HVAC Drive FC102. Low-voltage inverter. Supply voltage 3AC 200-240 V. Power 15 kw. Output current 59,4 A, . Frame size B4. IP 20
VLT HVAC Drive FC102. Low-voltage inverter. Supply voltage 3AC 200-240 V. Power 18 kw. Output current 74,8 A, . Frame size B4. IP 20
VLT HVAC Drive FC102. Low-voltage inverter. Supply voltage 3AC 200-240 V. Power 22 kw. Output current 88 A, . Frame size C3. IP 20
VLT HVAC Drive FC102. Low-voltage inverter. Supply voltage 3AC 200-240 V. Power 30 kw. Output current 115 A, . Frame size C3. IP 20
VLT HVAC Drive FC102. Low-voltage inverter. Supply voltage 3AC 200-240 V. Power 37 kw. Output current 143 A, . Frame size C4. IP 20
VLT HVAC Drive FC102. Low-voltage inverter. Supply voltage 3AC 200-240 V. Power 1,1 kw. Output current 6,6 A, . Frame size A2. IP 21
VLT HVAC Drive FC102. Low-voltage inverter. Supply voltage 3AC 200-240 V. Power 1,5 kw. Output current 7,5 A, . Frame size A2. IP 21
VLT HVAC Drive FC102. Low-voltage inverter. Supply voltage 3AC 200-240 V. Power 2,2 kw. Output current 10,6 A, . Frame size A2. IP 21
VLT HVAC Drive FC102. Low-voltage inverter. Supply voltage 3AC 200-240 V. Power 3 kw. Output current 12,5 A, . Frame size A3. IP 21
VLT HVAC Drive FC102. Low-voltage inverter. Supply voltage 3AC 200-240 V. Power 3,7 kw. Output current 16,7 A, . Frame size A3. IP 21
VLT HVAC Drive FC102. Low-voltage inverter. Supply voltage 3AC 200-240 V. Power 5,5 kw. Output current 24,2 A, . Frame size B1. IP 21
VLT HVAC Drive FC102. Low-voltage inverter. Supply voltage 3AC 200-240 V. Power 7,5 kw. Output current 30,8 A, . Frame size B1. IP 21
VLT HVAC Drive FC102. Low-voltage inverter. Supply voltage 3AC 200-240 V. Power 11 kw. Output current 46,2 A, . Frame size B1. IP 21
VLT HVAC Drive FC102. Low-voltage inverter. Supply voltage 3AC 200-240 V. Power 15 kw. Output current 59,4 A, . Frame size B2. IP 21
VLT HVAC Drive FC102. Low-voltage inverter. Supply voltage 3AC 200-240 V. Power 18 kw. Output current 74,8 A, . Frame size C1. IP 21
VLT HVAC Drive FC102. Low-voltage inverter. Supply voltage 3AC 200-240 V. Power 22 kw. Output current 88 A, . Frame size C1. IP 21
VLT HVAC Drive FC102. Low-voltage inverter. Supply voltage 3AC 200-240 V. Power 30 kw. Output current 115 A, . Frame size C1. IP 21
VLT HVAC Drive FC102. Low-voltage inverter. Supply voltage 3AC 200-240 V. Power 37 kw. Output current 143 A, . Frame size C2. IP 21
VLT HVAC Drive FC102. Low-voltage inverter. Supply voltage 3AC 200-240 V. Power 1,1 kw. Output current 6,6 A, . Frame size A5. IP 55
VLT HVAC Drive FC102. Low-voltage inverter. Supply voltage 3AC 200-240 V. Power 1,5 kw. Output current 7,5 A, . Frame size A5. IP 55
VLT HVAC Drive FC102. Low-voltage inverter. Supply voltage 3AC 200-240 V. Power 2,2 kw. Output current 10,6 A, . Frame size A5. IP 55
VLT HVAC Drive FC102. Low-voltage inverter. Supply voltage 3AC 200-240 V. Power 3 kw. Output current 12,5 A, . Frame size A5. IP 55
VLT HVAC Drive FC102. Low-voltage inverter. Supply voltage 3AC 200-240 V. Power 3,7 kw. Output current 16,7 A, . Frame size A5. IP 55
VLT HVAC Drive FC102. Low-voltage inverter. Supply voltage 3AC 200-240 V. Power 5,5 kw. Output current 24,2 A, . Frame size B1. IP 55
VLT HVAC Drive FC102. Low-voltage inverter. Supply voltage 3AC 200-240 V. Power 7,5 kw. Output current 30,8 A, . Frame size B1. IP 55
VLT HVAC Drive FC102. Low-voltage inverter. Supply voltage 3AC 200-240 V. Power 11 kw. Output current 46,2 A, . Frame size B1. IP 55
VLT HVAC Drive FC102. Low-voltage inverter. Supply voltage 3AC 200-240 V. Power 15 kw. Output current 59,4 A, . Frame size B2. IP 55
VLT HVAC Drive FC102. Low-voltage inverter. Supply voltage 3AC 200-240 V. Power 18 kw. Output current 74,8 A, . Frame size C1. IP 55
VLT HVAC Drive FC102. Low-voltage inverter. Supply voltage 3AC 200-240 V. Power 22 kw. Output current 88 A, . Frame size C1. IP 55
VLT HVAC Drive FC102. Low-voltage inverter. Supply voltage 3AC 200-240 V. Power 30 kw. Output current 115 A, . Frame size C1. IP 55
VLT HVAC Drive FC102. Low-voltage inverter. Supply voltage 3AC 200-240 V. Power 37 kw. Output current 143 A, . Frame size C2. IP 55
VLT HVAC Drive FC102. Low-voltage inverter. Supply voltage 3AC 200-240 V. Power 1,1 kw. Output current 6,6 A, . Frame size A5. IP 56
VLT HVAC Drive FC102. Low-voltage inverter. Supply voltage 3AC 200-240 V. Power 1,5 kw. Output current 7,5 A, . Frame size A5. IP 56
VLT HVAC Drive FC102. Low-voltage inverter. Supply voltage 3AC 200-240 V. Power 2,2 kw. Output current 10,6 A, . Frame size A5. IP 56
VLT HVAC Drive FC102. Low-voltage inverter. Supply voltage 3AC 200-240 V. Power 3 kw. Output current 12,5 A, . Frame size A5. IP 56
VLT HVAC Drive FC102. Low-voltage inverter. Supply voltage 3AC 200-240 V. Power 3,7 kw. Output current 16,7 A, . Frame size A5. IP 56
VLT HVAC Drive FC102. Low-voltage inverter. Supply voltage 3AC 200-240 V. Power 5,5 kw. Output current 24,2 A, . Frame size B1. IP 56
VLT HVAC Drive FC102. Low-voltage inverter. Supply voltage 3AC 200-240 V. Power 7,5 kw. Output current 30,8 A, . Frame size B1. IP 56
VLT HVAC Drive FC102. Low-voltage inverter. Supply voltage 3AC 200-240 V. Power 11 kw. Output current 46,2 A, . Frame size B1. IP 56
VLT HVAC Drive FC102. Low-voltage inverter. Supply voltage 3AC 200-240 V. Power 15 kw. Output current 59,4 A, . Frame size B2. IP 56
VLT HVAC Drive FC102. Low-voltage inverter. Supply voltage 3AC 200-240 V. Power 18 kw. Output current 74,8 A, . Frame size C1. IP 56
VLT HVAC Drive FC102. Low-voltage inverter. Supply voltage 3AC 200-240 V. Power 22 kw. Output current 88 A, . Frame size C1. IP 56
VLT HVAC Drive FC102. Low-voltage inverter. Supply voltage 3AC 200-240 V. Power 30 kw. Output current 115 A, . Frame size C1. IP 56
VLT HVAC Drive FC102. Low-voltage inverter. Supply voltage 3AC 200-240 V. Power 37 kw. Output current 143 A, . Frame size C2. IP 56
VLT HVAC Drive FC102. Low-voltage inverter. Supply voltage 3AC 380-480 V. Power 110 kw. Output current <440 v 212 A, > 440 v 190 A. Frame size D3. IP 0
VLT HVAC Drive FC102. Low-voltage inverter. Supply voltage 3AC 380-480 V. Power 132 kw. Output current <440 v 260 A, > 440 v 240 A. Frame size D3. IP 0
VLT HVAC Drive FC102. Low-voltage inverter. Supply voltage 3AC 380-480 V. Power 160 kw. Output current <440 v 315 A, > 440 v 302 A. Frame size D4. IP 0
VLT HVAC Drive FC102. Low-voltage inverter. Supply voltage 3AC 380-480 V. Power 200 kw. Output current <440 v 395 A, > 440 v 361 A. Frame size D4. IP 0
VLT HVAC Drive FC102. Low-voltage inverter. Supply voltage 3AC 380-480 V. Power 250 kw. Output current <440 v 480 A, > 440 v 443 A. Frame size D4. IP 0
VLT HVAC Drive FC102. Low-voltage inverter. Supply voltage 3AC 380-480 V. Power 315 kw. Output current <440 v 600 A, > 440 v 540 A. Frame size E2. IP 0
VLT HVAC Drive FC102. Low-voltage inverter. Supply voltage 3AC 380-480 V. Power 355 kw. Output current <440 v 658 A, > 440 v 590 A. Frame size E2. IP 0
VLT HVAC Drive FC102. Low-voltage inverter. Supply voltage 3AC 380-480 V. Power 400 kw. Output current <440 v 745 A, > 440 v 678 A. Frame size E2. IP 0
VLT HVAC Drive FC102. Low-voltage inverter. Supply voltage 3AC 380-480 V. Power 450 kw. Output current <440 v 800 A, > 440 v 730 A. Frame size E2. IP 0
VLT HVAC Drive FC102. Low-voltage inverter. Supply voltage 3AC 380-480 V. Power 1,1 kw. Output current <440 v 3 A, > 440 v 2,7 A. Frame size A2. IP 20
VLT HVAC Drive FC102. Low-voltage inverter. Supply voltage 3AC 380-480 V. Power 1,5 kw. Output current <440 v 4,1 A, > 440 v 3,4 A. Frame size A2. IP 20
VLT HVAC Drive FC102. Low-voltage inverter. Supply voltage 3AC 380-480 V. Power 2,2 kw. Output current <440 v 5,6 A, > 440 v 4,8 A. Frame size A2. IP 20
VLT HVAC Drive FC102. Low-voltage inverter. Supply voltage 3AC 380-480 V. Power 3 kw. Output current <440 v 7,2 A, > 440 v 6,3 A. Frame size A2. IP 20
VLT HVAC Drive FC102. Low-voltage inverter. Supply voltage 3AC 380-480 V. Power 4 kw. Output current <440 v 10 A, > 440 v 8,2 A. Frame size A2. IP 20
VLT HVAC Drive FC102. Low-voltage inverter. Supply voltage 3AC 380-480 V. Power 5,5 kw. Output current <440 v 13 A, > 440 v 11 A. Frame size A3. IP 20
VLT HVAC Drive FC102. Low-voltage inverter. Supply voltage 3AC 380-480 V. Power 7,5 kw. Output current <440 v 16 A, > 440 v 14,5 A. Frame size A3. IP 20
VLT HVAC Drive FC102. Low-voltage inverter. Supply voltage 3AC 380-480 V. Power 11 kw. Output current <440 v 24 A, > 440 v 21 A. Frame size B3. IP 20
VLT HVAC Drive FC102. Low-voltage inverter. Supply voltage 3AC 380-480 V. Power 15 kw. Output current <440 v 32 A, > 440 v 27 A. Frame size B3. IP 20
VLT HVAC Drive FC102. Low-voltage inverter. Supply voltage 3AC 380-480 V. Power 18 kw. Output current <440 v 37,5 A, > 440 v 34 A. Frame size B3. IP 20
VLT HVAC Drive FC102. Low-voltage inverter. Supply voltage 3AC 380-480 V. Power 22 kw. Output current <440 v 44 A, > 440 v 40 A. Frame size B4. IP 20
VLT HVAC Drive FC102. Low-voltage inverter. Supply voltage 3AC 380-480 V. Power 30 kw. Output current <440 v 61 A, > 440 v 52 A. Frame size B4. IP 20
VLT HVAC Drive FC102. Low-voltage inverter. Supply voltage 3AC 380-480 V. Power 37 kw. Output current <440 v 73 A, > 440 v 65 A. Frame size B4. IP 20
VLT HVAC Drive FC102. Low-voltage inverter. Supply voltage 3AC 380-480 V. Power 45 kw. Output current <440 v 90 A, > 440 v 80 A. Frame size C3. IP 20
VLT HVAC Drive FC102. Low-voltage inverter. Supply voltage 3AC 380-480 V. Power 55 kw. Output current <440 v 106 A, > 440 v 105 A. Frame size C3. IP 20
VLT HVAC Drive FC102. Low-voltage inverter. Supply voltage 3AC 380-480 V. Power 75 kw. Output current <440 v 147 A, > 440 v 130 A. Frame size C4. IP 20
VLT HVAC Drive FC102. Low-voltage inverter. Supply voltage 3AC 380-480 V. Power 90 kw. Output current <440 v 177 A, > 440 v 160 A. Frame size C4. IP 20
VLT HVAC Drive FC102. Low-voltage inverter. Supply voltage 3AC 380-480 V. Power 1,1 kw. Output current <440 v 3 A, > 440 v 2,7 A. Frame size A2. IP 21
VLT HVAC Drive FC102. Low-voltage inverter. Supply voltage 3AC 380-480 V. Power 1,5 kw. Output current <440 v 4,1 A, > 440 v 3,4 A. Frame size A2. IP 21
VLT HVAC Drive FC102. Low-voltage inverter. Supply voltage 3AC 380-480 V. Power 2,2 kw. Output current <440 v 5,6 A, > 440 v 4,8 A. Frame size A2. IP 21
VLT HVAC Drive FC102. Low-voltage inverter. Supply voltage 3AC 380-480 V. Power 3 kw. Output current <440 v 7,2 A, > 440 v 6,3 A. Frame size A2. IP 21
VLT HVAC Drive FC102. Low-voltage inverter. Supply voltage 3AC 380-480 V. Power 4 kw. Output current <440 v 10 A, > 440 v 8,2 A. Frame size A2. IP 21
VLT HVAC Drive FC102. Low-voltage inverter. Supply voltage 3AC 380-480 V. Power 5,5 kw. Output current <440 v 13 A, > 440 v 11 A. Frame size A3. IP 21
VLT HVAC Drive FC102. Low-voltage inverter. Supply voltage 3AC 380-480 V. Power 7,5 kw. Output current <440 v 16 A, > 440 v 14,5 A. Frame size A3. IP 21
VLT HVAC Drive FC102. Low-voltage inverter. Supply voltage 3AC 380-480 V. Power 11 kw. Output current <440 v 24 A, > 440 v 21 A. Frame size B1. IP 21
VLT HVAC Drive FC102. Low-voltage inverter. Supply voltage 3AC 380-480 V. Power 15 kw. Output current <440 v 32 A, > 440 v 27 A. Frame size B1. IP 21
VLT HVAC Drive FC102. Low-voltage inverter. Supply voltage 3AC 380-480 V. Power 18 kw. Output current <440 v 37,5 A, > 440 v 34 A. Frame size B1. IP 21
VLT HVAC Drive FC102. Low-voltage inverter. Supply voltage 3AC 380-480 V. Power 22 kw. Output current <440 v 44 A, > 440 v 40 A. Frame size B2. IP 21
VLT HVAC Drive FC102. Low-voltage inverter. Supply voltage 3AC 380-480 V. Power 30 kw. Output current <440 v 61 A, > 440 v 52 A. Frame size B2. IP 21
VLT HVAC Drive FC102. Low-voltage inverter. Supply voltage 3AC 380-480 V. Power 37 kw. Output current <440 v 73 A, > 440 v 65 A. Frame size C1. IP 21
VLT HVAC Drive FC102. Low-voltage inverter. Supply voltage 3AC 380-480 V. Power 45 kw. Output current <440 v 90 A, > 440 v 80 A. Frame size C1. IP 21
VLT HVAC Drive FC102. Low-voltage inverter. Supply voltage 3AC 380-480 V. Power 55 kw. Output current <440 v 106 A, > 440 v 105 A. Frame size C1. IP 21
VLT HVAC Drive FC102. Low-voltage inverter. Supply voltage 3AC 380-480 V. Power 75 kw. Output current <440 v 147 A, > 440 v 130 A. Frame size C2. IP 21
VLT HVAC Drive FC102. Low-voltage inverter. Supply voltage 3AC 380-480 V. Power 90 kw. Output current <440 v 177 A, > 440 v 160 A. Frame size C2. IP 21
VLT HVAC Drive FC102. Low-voltage inverter. Supply voltage 3AC 380-480 V. Power 110 kw. Output current <440 v 212 A, > 440 v 190 A. Frame size D1. IP 21
VLT HVAC Drive FC102. Low-voltage inverter. Supply voltage 3AC 380-480 V. Power 132 kw. Output current <440 v 260 A, > 440 v 240 A. Frame size D1. IP 21
VLT HVAC Drive FC102. Low-voltage inverter. Supply voltage 3AC 380-480 V. Power 160 kw. Output current <440 v 315 A, > 440 v 302 A. Frame size D2. IP 21
VLT HVAC Drive FC102. Low-voltage inverter. Supply voltage 3AC 380-480 V. Power 200 kw. Output current <440 v 395 A, > 440 v 361 A. Frame size D2. IP 21
VLT HVAC Drive FC102. Low-voltage inverter. Supply voltage 3AC 380-480 V. Power 250 kw. Output current <440 v 480 A, > 440 v 443 A. Frame size D2. IP 21
VLT HVAC Drive FC102. Low-voltage inverter. Supply voltage 3AC 380-480 V. Power 315 kw. Output current <440 v 600 A, > 440 v 540 A. Frame size E1. IP 21
VLT HVAC Drive FC102. Low-voltage inverter. Supply voltage 3AC 380-480 V. Power 355 kw. Output current <440 v 658 A, > 440 v 590 A. Frame size E1. IP 21
VLT HVAC Drive FC102. Low-voltage inverter. Supply voltage 3AC 380-480 V. Power 400 kw. Output current <440 v 745 A, > 440 v 678 A. Frame size E1. IP 21
VLT HVAC Drive FC102. Low-voltage inverter. Supply voltage 3AC 380-480 V. Power 450 kw. Output current <440 v 800 A, > 440 v 730 A. Frame size E1. IP 21
VLT HVAC Drive FC102. Low-voltage inverter. Supply voltage 3AC 380-480 V. Power 500 kw. Output current <440 v 880 A, > 440 v 780 A. Frame size F1/F3. IP 21
VLT HVAC Drive FC102. Low-voltage inverter. Supply voltage 3AC 380-480 V. Power 560 kw. Output current <440 v 990 A, > 440 v 890 A. Frame size F1/F3. IP 21
VLT HVAC Drive FC102. Low-voltage inverter. Supply voltage 3AC 380-480 V. Power 630 kw. Output current <440 v 1120 A, > 440 v 1050 A. Frame size F1/F3. IP 21
VLT HVAC Drive FC102. Low-voltage inverter. Supply voltage 3AC 380-480 V. Power 710 kw. Output current <440 v 1260 A, > 440 v 1160 A. Frame size F1/F3. IP 21
VLT HVAC Drive FC102. Low-voltage inverter. Supply voltage 3AC 380-480 V. Power 800 kw. Output current <440 v 1460 A, > 440 v 1380 A. Frame size F2/F4. IP 21
VLT HVAC Drive FC102. Low-voltage inverter. Supply voltage 3AC 380-480 V. Power 1000 kw. Output current <440 v 1720 A, > 440 v 1530 A. Frame size F2/F4. IP 21
VLT HVAC Drive FC102. Low-voltage inverter. Supply voltage 3AC 380-480 V. Power 110 kw. Output current <440 v 212 A, > 440 v 190 A. Frame size D1. IP 54
VLT HVAC Drive FC102. Low-voltage inverter. Supply voltage 3AC 380-480 V. Power 132 kw. Output current <440 v 260 A, > 440 v 240 A. Frame size D1. IP 54
VLT HVAC Drive FC102. Low-voltage inverter. Supply voltage 3AC 380-480 V. Power 160 kw. Output current <440 v 315 A, > 440 v 302 A. Frame size D2. IP 54
VLT HVAC Drive FC102. Low-voltage inverter. Supply voltage 3AC 380-480 V. Power 200 kw. Output current <440 v 395 A, > 440 v 361 A. Frame size D2. IP 54
VLT HVAC Drive FC102. Low-voltage inverter. Supply voltage 3AC 380-480 V. Power 250 kw. Output current <440 v 480 A, > 440 v 443 A. Frame size D2. IP 54
VLT HVAC Drive FC102. Low-voltage inverter. Supply voltage 3AC 380-480 V. Power 315 kw. Output current <440 v 600 A, > 440 v 540 A. Frame size E1. IP 54
VLT HVAC Drive FC102. Low-voltage inverter. Supply voltage 3AC 380-480 V. Power 355 kw. Output current <440 v 658 A, > 440 v 590 A. Frame size E1. IP 54
VLT HVAC Drive FC102. Low-voltage inverter. Supply voltage 3AC 380-480 V. Power 400 kw. Output current <440 v 745 A, > 440 v 678 A. Frame size E1. IP 54
VLT HVAC Drive FC102. Low-voltage inverter. Supply voltage 3AC 380-480 V. Power 450 kw. Output current <440 v 800 A, > 440 v 730 A. Frame size E1. IP 54
VLT HVAC Drive FC102. Low-voltage inverter. Supply voltage 3AC 380-480 V. Power 500 kw. Output current <440 v 880 A, > 440 v 780 A. Frame size F1/F3. IP 54
VLT HVAC Drive FC102. Low-voltage inverter. Supply voltage 3AC 380-480 V. Power 560 kw. Output current <440 v 990 A, > 440 v 890 A. Frame size F1/F3. IP 54
VLT HVAC Drive FC102. Low-voltage inverter. Supply voltage 3AC 380-480 V. Power 630 kw. Output current <440 v 1120 A, > 440 v 1050 A. Frame size F1/F3. IP 54
VLT HVAC Drive FC102. Low-voltage inverter. Supply voltage 3AC 380-480 V. Power 710 kw. Output current <440 v 1260 A, > 440 v 1160 A. Frame size F1/F3. IP 54
VLT HVAC Drive FC102. Low-voltage inverter. Supply voltage 3AC 380-480 V. Power 800 kw. Output current <440 v 1460 A, > 440 v 1380 A. Frame size F2/F4. IP 54
VLT HVAC Drive FC102. Low-voltage inverter. Supply voltage 3AC 380-480 V. Power 1000 kw. Output current <440 v 1720 A, > 440 v 1530 A. Frame size F2/F4. IP 54
VLT HVAC Drive FC102. Low-voltage inverter. Supply voltage 3AC 380-480 V. Power 1,1 kw. Output current <440 v 3 A, > 440 v 2,7 A. Frame size A5. IP 55
VLT HVAC Drive FC102. Low-voltage inverter. Supply voltage 3AC 380-480 V. Power 1,5 kw. Output current <440 v 4,1 A, > 440 v 3,4 A. Frame size A5. IP 55
VLT HVAC Drive FC102. Low-voltage inverter. Supply voltage 3AC 380-480 V. Power 2,2 kw. Output current <440 v 5,6 A, > 440 v 4,8 A. Frame size A5. IP 55
VLT HVAC Drive FC102. Low-voltage inverter. Supply voltage 3AC 380-480 V. Power 3 kw. Output current <440 v 7,2 A, > 440 v 6,3 A. Frame size A5. IP 55
VLT HVAC Drive FC102. Low-voltage inverter. Supply voltage 3AC 380-480 V. Power 4 kw. Output current <440 v 10 A, > 440 v 8,2 A. Frame size A5. IP 55
VLT HVAC Drive FC102. Low-voltage inverter. Supply voltage 3AC 380-480 V. Power 5,5 kw. Output current <440 v 13 A, > 440 v 11 A. Frame size A5. IP 55
VLT HVAC Drive FC102. Low-voltage inverter. Supply voltage 3AC 380-480 V. Power 7,5 kw. Output current <440 v 16 A, > 440 v 14,5 A. Frame size A5. IP 55
VLT HVAC Drive FC102. Low-voltage inverter. Supply voltage 3AC 380-480 V. Power 11 kw. Output current <440 v 24 A, > 440 v 21 A. Frame size B1. IP 55
VLT HVAC Drive FC102. Low-voltage inverter. Supply voltage 3AC 380-480 V. Power 15 kw. Output current <440 v 32 A, > 440 v 27 A. Frame size B1. IP 55
VLT HVAC Drive FC102. Low-voltage inverter. Supply voltage 3AC 380-480 V. Power 18 kw. Output current <440 v 37,5 A, > 440 v 34 A. Frame size B1. IP 55
VLT HVAC Drive FC102. Low-voltage inverter. Supply voltage 3AC 380-480 V. Power 22 kw. Output current <440 v 44 A, > 440 v 40 A. Frame size B2. IP 55
VLT HVAC Drive FC102. Low-voltage inverter. Supply voltage 3AC 380-480 V. Power 30 kw. Output current <440 v 61 A, > 440 v 52 A. Frame size B2. IP 55
VLT HVAC Drive FC102. Low-voltage inverter. Supply voltage 3AC 380-480 V. Power 37 kw. Output current <440 v 73 A, > 440 v 65 A. Frame size C1. IP 55
VLT HVAC Drive FC102. Low-voltage inverter. Supply voltage 3AC 380-480 V. Power 45 kw. Output current <440 v 90 A, > 440 v 80 A. Frame size C1. IP 55
VLT HVAC Drive FC102. Low-voltage inverter. Supply voltage 3AC 380-480 V. Power 55 kw. Output current <440 v 106 A, > 440 v 105 A. Frame size C1. IP 55
VLT HVAC Drive FC102. Low-voltage inverter. Supply voltage 3AC 380-480 V. Power 75 kw. Output current <440 v 147 A, > 440 v 130 A. Frame size C2. IP 55
VLT HVAC Drive FC102. Low-voltage inverter. Supply voltage 3AC 380-480 V. Power 90 kw. Output current <440 v 177 A, > 440 v 160 A. Frame size C2. IP 55
VLT HVAC Drive FC102. Low-voltage inverter. Supply voltage 3AC 380-480 V. Power 1,1 kw. Output current <440 v 3 A, > 440 v 2,7 A. Frame size A5. IP 66
VLT HVAC Drive FC102. Low-voltage inverter. Supply voltage 3AC 380-480 V. Power 1,5 kw. Output current <440 v 4,1 A, > 440 v 3,4 A. Frame size A5. IP 66
VLT HVAC Drive FC102. Low-voltage inverter. Supply voltage 3AC 380-480 V. Power 2,2 kw. Output current <440 v 5,6 A, > 440 v 4,8 A. Frame size A5. IP 66
VLT HVAC Drive FC102. Low-voltage inverter. Supply voltage 3AC 380-480 V. Power 3 kw. Output current <440 v 7,2 A, > 440 v 6,3 A. Frame size A5. IP 66
VLT HVAC Drive FC102. Low-voltage inverter. Supply voltage 3AC 380-480 V. Power 4 kw. Output current <440 v 10 A, > 440 v 8,2 A. Frame size A5. IP 66
VLT HVAC Drive FC102. Low-voltage inverter. Supply voltage 3AC 380-480 V. Power 5,5 kw. Output current <440 v 13 A, > 440 v 11 A. Frame size A5. IP 66
VLT HVAC Drive FC102. Low-voltage inverter. Supply voltage 3AC 380-480 V. Power 7,5 kw. Output current <440 v 16 A, > 440 v 14,5 A. Frame size A5. IP 66
VLT HVAC Drive FC102. Low-voltage inverter. Supply voltage 3AC 380-480 V. Power 11 kw. Output current <440 v 24 A, > 440 v 21 A. Frame size B1. IP 66
VLT HVAC Drive FC102. Low-voltage inverter. Supply voltage 3AC 380-480 V. Power 15 kw. Output current <440 v 32 A, > 440 v 27 A. Frame size B1. IP 66
VLT HVAC Drive FC102. Low-voltage inverter. Supply voltage 3AC 380-480 V. Power 18 kw. Output current <440 v 37,5 A, > 440 v 34 A. Frame size B1. IP 66
VLT HVAC Drive FC102. Low-voltage inverter. Supply voltage 3AC 380-480 V. Power 22 kw. Output current <440 v 44 A, > 440 v 40 A. Frame size B2. IP 66
VLT HVAC Drive FC102. Low-voltage inverter. Supply voltage 3AC 380-480 V. Power 30 kw. Output current <440 v 61 A, > 440 v 52 A. Frame size B2. IP 66
VLT HVAC Drive FC102. Low-voltage inverter. Supply voltage 3AC 380-480 V. Power 37 kw. Output current <440 v 73 A, > 440 v 65 A. Frame size C1. IP 66
VLT HVAC Drive FC102. Low-voltage inverter. Supply voltage 3AC 380-480 V. Power 45 kw. Output current <440 v 90 A, > 440 v 80 A. Frame size C1. IP 66
VLT HVAC Drive FC102. Low-voltage inverter. Supply voltage 3AC 380-480 V. Power 55 kw. Output current <440 v 106 A, > 440 v 105 A. Frame size C1. IP 66
VLT HVAC Drive FC102. Low-voltage inverter. Supply voltage 3AC 380-480 V. Power 75 kw. Output current <440 v 147 A, > 440 v 130 A. Frame size C2. IP 66
VLT HVAC Drive FC102. Low-voltage inverter. Supply voltage 3AC 380-480 V. Power 90 kw. Output current <440 v 177 A, > 440 v 160 A. Frame size C2. IP 66
VLT HVAC Drive FC102. Low-voltage inverter. Supply voltage 3AC 525-600 V. Power 1,1 kw. Output current <550 v 2,6 A, > 550 v 2,4 A. Frame size A3. IP 20
VLT HVAC Drive FC102. Low-voltage inverter. Supply voltage 3AC 525-600 V. Power 1,5 kw. Output current <550 v 2,9 A, > 550 v 2,7 A. Frame size A3. IP 20
VLT HVAC Drive FC102. Low-voltage inverter. Supply voltage 3AC 525-600 V. Power 2,2 kw. Output current <550 v 4,1 A, > 550 v 3,9 A. Frame size A3. IP 20
VLT HVAC Drive FC102. Low-voltage inverter. Supply voltage 3AC 525-600 V. Power 3 kw. Output current <550 v 5,2 A, > 550 v 4,9 A. Frame size A3. IP 20
VLT HVAC Drive FC102. Low-voltage inverter. Supply voltage 3AC 525-600 V. Power 4 kw. Output current <550 v 6,4 A, > 550 v 6,1 A. Frame size A3. IP 20
VLT HVAC Drive FC102. Low-voltage inverter. Supply voltage 3AC 525-600 V. Power 5,5 kw. Output current <550 v 9,5 A, > 550 v 9 A. Frame size A3. IP 20
VLT HVAC Drive FC102. Low-voltage inverter. Supply voltage 3AC 525-600 V. Power 7,5 kw. Output current <550 v 11,5 A, > 550 v 11 A. Frame size A3. IP 20
VLT HVAC Drive FC102. Low-voltage inverter. Supply voltage 3AC 525-600 V. Power 11 kw. Output current <550 v 19 A, > 550 v 18 A. Frame size B3. IP 20
VLT HVAC Drive FC102. Low-voltage inverter. Supply voltage 3AC 525-600 V. Power 15 kw. Output current <550 v 23 A, > 550 v 22 A. Frame size B3. IP 20
VLT HVAC Drive FC102. Low-voltage inverter. Supply voltage 3AC 525-600 V. Power 18 kw. Output current <550 v 28 A, > 550 v 27 A. Frame size B3. IP 20
VLT HVAC Drive FC102. Low-voltage inverter. Supply voltage 3AC 525-600 V. Power 22 kw. Output current <550 v 36 A, > 550 v 34 A. Frame size B4. IP 20
VLT HVAC Drive FC102. Low-voltage inverter. Supply voltage 3AC 525-600 V. Power 30 kw. Output current <550 v 43 A, > 550 v 41 A. Frame size B4. IP 20
VLT HVAC Drive FC102. Low-voltage inverter. Supply voltage 3AC 525-600 V. Power 37 kw. Output current <550 v 54 A, > 550 v 52 A. Frame size B4. IP 20
VLT HVAC Drive FC102. Low-voltage inverter. Supply voltage 3AC 525-600 V. Power 45 kw. Output current <550 v 65 A, > 550 v 62 A. Frame size C3. IP 20
VLT HVAC Drive FC102. Low-voltage inverter. Supply voltage 3AC 525-600 V. Power 55 kw. Output current <550 v 87 A, > 550 v 83 A. Frame size C3. IP 20
VLT HVAC Drive FC102. Low-voltage inverter. Supply voltage 3AC 525-600 V. Power 75 kw. Output current <550 v 105 A, > 550 v 100 A. Frame size C4. IP 20
VLT HVAC Drive FC102. Low-voltage inverter. Supply voltage 3AC 525-600 V. Power 90 kw. Output current <550 v 137 A, > 550 v 131 A. Frame size C4. IP 20
VLT HVAC Drive FC102. Low-voltage inverter. Supply voltage 3AC 525-600 V. Power 1,1 kw. Output current <550 v 2,6 A, > 550 v 2,4 A. Frame size A3. IP 21
VLT HVAC Drive FC102. Low-voltage inverter. Supply voltage 3AC 525-600 V. Power 1,5 kw. Output current <550 v 2,9 A, > 550 v 2,7 A. Frame size A3. IP 21
VLT HVAC Drive FC102. Low-voltage inverter. Supply voltage 3AC 525-600 V. Power 2,2 kw. Output current <550 v 4,1 A, > 550 v 3,9 A. Frame size A3. IP 21
VLT HVAC Drive FC102. Low-voltage inverter. Supply voltage 3AC 525-600 V. Power 3 kw. Output current <550 v 5,2 A, > 550 v 4,9 A. Frame size A3. IP 21
VLT HVAC Drive FC102. Low-voltage inverter. Supply voltage 3AC 525-600 V. Power 4 kw. Output current <550 v 6,4 A, > 550 v 6,1 A. Frame size A3. IP 21
VLT HVAC Drive FC102. Low-voltage inverter. Supply voltage 3AC 525-600 V. Power 5,5 kw. Output current <550 v 9,5 A, > 550 v 9 A. Frame size A3. IP 21
VLT HVAC Drive FC102. Low-voltage inverter. Supply voltage 3AC 525-600 V. Power 7,5 kw. Output current <550 v 11,5 A, > 550 v 11 A. Frame size A3. IP 21
VLT HVAC Drive FC102. Low-voltage inverter. Supply voltage 3AC 525-600 V. Power 11 kw. Output current <550 v 19 A, > 550 v 18 A. Frame size B1. IP 21
VLT HVAC Drive FC102. Low-voltage inverter. Supply voltage 3AC 525-600 V. Power 15 kw. Output current <550 v 23 A, > 550 v 22 A. Frame size B1. IP 21
VLT HVAC Drive FC102. Low-voltage inverter. Supply voltage 3AC 525-600 V. Power 18 kw. Output current <550 v 28 A, > 550 v 27 A. Frame size B1. IP 21
VLT HVAC Drive FC102. Low-voltage inverter. Supply voltage 3AC 525-600 V. Power 22 kw. Output current <550 v 36 A, > 550 v 34 A. Frame size B2. IP 21
VLT HVAC Drive FC102. Low-voltage inverter. Supply voltage 3AC 525-600 V. Power 30 kw. Output current <550 v 43 A, > 550 v 41 A. Frame size B2. IP 21
VLT HVAC Drive FC102. Low-voltage inverter. Supply voltage 3AC 525-600 V. Power 37 kw. Output current <550 v 54 A, > 550 v 52 A. Frame size C1. IP 21
VLT HVAC Drive FC102. Low-voltage inverter. Supply voltage 3AC 525-600 V. Power 45 kw. Output current <550 v 65 A, > 550 v 62 A. Frame size C1. IP 21
VLT HVAC Drive FC102. Low-voltage inverter. Supply voltage 3AC 525-600 V. Power 55 kw. Output current <550 v 87 A, > 550 v 83 A. Frame size C1. IP 21
VLT HVAC Drive FC102. Low-voltage inverter. Supply voltage 3AC 525-600 V. Power 75 kw. Output current <550 v 105 A, > 550 v 100 A. Frame size C2. IP 21
VLT HVAC Drive FC102. Low-voltage inverter. Supply voltage 3AC 525-600 V. Power 90 kw. Output current <550 v 137 A, > 550 v 131 A. Frame size C2. IP 21
VLT HVAC Drive FC102. Low-voltage inverter. Supply voltage 3AC 525-600 V. Power 1,1 kw. Output current <550 v 2,6 A, > 550 v 2,4 A. Frame size A5. IP 55
VLT HVAC Drive FC102. Low-voltage inverter. Supply voltage 3AC 525-600 V. Power 1,5 kw. Output current <550 v 2,9 A, > 550 v 2,7 A. Frame size A5. IP 55
VLT HVAC Drive FC102. Low-voltage inverter. Supply voltage 3AC 525-600 V. Power 2,2 kw. Output current <550 v 4,1 A, > 550 v 3,9 A. Frame size A5. IP 55
VLT HVAC Drive FC102. Low-voltage inverter. Supply voltage 3AC 525-600 V. Power 3 kw. Output current <550 v 5,2 A, > 550 v 4,9 A. Frame size A5. IP 55
VLT HVAC Drive FC102. Low-voltage inverter. Supply voltage 3AC 525-600 V. Power 4 kw. Output current <550 v 6,4 A, > 550 v 6,1 A. Frame size A5. IP 55
VLT HVAC Drive FC102. Low-voltage inverter. Supply voltage 3AC 525-600 V. Power 5,5 kw. Output current <550 v 9,5 A, > 550 v 9 A. Frame size A5. IP 55
VLT HVAC Drive FC102. Low-voltage inverter. Supply voltage 3AC 525-600 V. Power 7,5 kw. Output current <550 v 11,5 A, > 550 v 11 A. Frame size A5. IP 55
VLT HVAC Drive FC102. Low-voltage inverter. Supply voltage 3AC 525-600 V. Power 11 kw. Output current <550 v 19 A, > 550 v 18 A. Frame size B1. IP 55
VLT HVAC Drive FC102. Low-voltage inverter. Supply voltage 3AC 525-600 V. Power 15 kw. Output current <550 v 23 A, > 550 v 22 A. Frame size B1. IP 55
VLT HVAC Drive FC102. Low-voltage inverter. Supply voltage 3AC 525-600 V. Power 18 kw. Output current <550 v 28 A, > 550 v 27 A. Frame size B1. IP 55
VLT HVAC Drive FC102. Low-voltage inverter. Supply voltage 3AC 525-600 V. Power 22 kw. Output current <550 v 36 A, > 550 v 34 A. Frame size B2. IP 55
VLT HVAC Drive FC102. Low-voltage inverter. Supply voltage 3AC 525-600 V. Power 30 kw. Output current <550 v 43 A, > 550 v 41 A. Frame size B2. IP 55
VLT HVAC Drive FC102. Low-voltage inverter. Supply voltage 3AC 525-600 V. Power 37 kw. Output current <550 v 54 A, > 550 v 52 A. Frame size C1. IP 55
VLT HVAC Drive FC102. Low-voltage inverter. Supply voltage 3AC 525-600 V. Power 45 kw. Output current <550 v 65 A, > 550 v 62 A. Frame size C1. IP 55
VLT HVAC Drive FC102. Low-voltage inverter. Supply voltage 3AC 525-600 V. Power 55 kw. Output current <550 v 87 A, > 550 v 83 A. Frame size C1. IP 55
VLT HVAC Drive FC102. Low-voltage inverter. Supply voltage 3AC 525-600 V. Power 75 kw. Output current <550 v 105 A, > 550 v 100 A. Frame size C2. IP 55
VLT HVAC Drive FC102. Low-voltage inverter. Supply voltage 3AC 525-600 V. Power 90 kw. Output current <550 v 137 A, > 550 v 131 A. Frame size C2. IP 55
VLT HVAC Drive FC102. Low-voltage inverter. Supply voltage 3AC 525-600 V. Power 1,1 kw. Output current <550 v 2,6 A, > 550 v 2,4 A. Frame size A5. IP 66
VLT HVAC Drive FC102. Low-voltage inverter. Supply voltage 3AC 525-600 V. Power 1,5 kw. Output current <550 v 2,9 A, > 550 v 2,7 A. Frame size A5. IP 66
VLT HVAC Drive FC102. Low-voltage inverter. Supply voltage 3AC 525-600 V. Power 2,2 kw. Output current <550 v 4,1 A, > 550 v 3,9 A. Frame size A5. IP 66
VLT HVAC Drive FC102. Low-voltage inverter. Supply voltage 3AC 525-600 V. Power 3 kw. Output current <550 v 5,2 A, > 550 v 4,9 A. Frame size A5. IP 66
VLT HVAC Drive FC102. Low-voltage inverter. Supply voltage 3AC 525-600 V. Power 4 kw. Output current <550 v 6,4 A, > 550 v 6,1 A. Frame size A5. IP 66
VLT HVAC Drive FC102. Low-voltage inverter. Supply voltage 3AC 525-600 V. Power 5,5 kw. Output current <550 v 9,5 A, > 550 v 9 A. Frame size A5. IP 66
VLT HVAC Drive FC102. Low-voltage inverter. Supply voltage 3AC 525-600 V. Power 7,5 kw. Output current <550 v 11,5 A, > 550 v 11 A. Frame size A5. IP 66
VLT HVAC Drive FC102. Low-voltage inverter. Supply voltage 3AC 525-600 V. Power 11 kw. Output current <550 v 19 A, > 550 v 18 A. Frame size B1. IP 66
VLT HVAC Drive FC102. Low-voltage inverter. Supply voltage 3AC 525-600 V. Power 15 kw. Output current <550 v 23 A, > 550 v 22 A. Frame size B1. IP 66
VLT HVAC Drive FC102. Low-voltage inverter. Supply voltage 3AC 525-600 V. Power 18 kw. Output current <550 v 28 A, > 550 v 27 A. Frame size B1. IP 66
VLT HVAC Drive FC102. Low-voltage inverter. Supply voltage 3AC 525-600 V. Power 22 kw. Output current <550 v 36 A, > 550 v 34 A. Frame size B2. IP 66
VLT HVAC Drive FC102. Low-voltage inverter. Supply voltage 3AC 525-600 V. Power 30 kw. Output current <550 v 43 A, > 550 v 41 A. Frame size B2. IP 66
VLT HVAC Drive FC102. Low-voltage inverter. Supply voltage 3AC 525-600 V. Power 37 kw. Output current <550 v 54 A, > 550 v 52 A. Frame size C1. IP 66
VLT HVAC Drive FC102. Low-voltage inverter. Supply voltage 3AC 525-600 V. Power 45 kw. Output current <550 v 65 A, > 550 v 62 A. Frame size C1. IP 66
VLT HVAC Drive FC102. Low-voltage inverter. Supply voltage 3AC 525-600 V. Power 55 kw. Output current <550 v 87 A, > 550 v 83 A. Frame size C1. IP 66
VLT HVAC Drive FC102. Low-voltage inverter. Supply voltage 3AC 525-600 V. Power 75 kw. Output current <550 v 105 A, > 550 v 100 A. Frame size C2. IP 66
VLT HVAC Drive FC102. Low-voltage inverter. Supply voltage 3AC 525-600 V. Power 90 kw. Output current <550 v 137 A, > 550 v 131 A. Frame size C2. IP 66
VLT HVAC Drive FC102. Low-voltage inverter. Supply voltage 3AC 525-690 V. Power 45 kw. Output current 550 v 56 A, 690 v 54 A. Frame size D3. IP 0
VLT HVAC Drive FC102. Low-voltage inverter. Supply voltage 3AC 525-690 V. Power 55 kw. Output current 550 v 76 A, 690 v 73 A. Frame size D3. IP 0
VLT HVAC Drive FC102. Low-voltage inverter. Supply voltage 3AC 525-690 V. Power 75 kw. Output current 550 v 90 A, 690 v 86 A. Frame size D3. IP 0
VLT HVAC Drive FC102. Low-voltage inverter. Supply voltage 3AC 525-690 V. Power 90 kw. Output current 550 v 113 A, 690 v 108 A. Frame size D3. IP 0
VLT HVAC Drive FC102. Low-voltage inverter. Supply voltage 3AC 525-690 V. Power 110 kw. Output current 550 v 137 A, 690 v 131 A. Frame size D3. IP 0
VLT HVAC Drive FC102. Low-voltage inverter. Supply voltage 3AC 525-690 V. Power 132 kw. Output current 550 v 162 A, 690 v 155 A. Frame size D3. IP 0
VLT HVAC Drive FC102. Low-voltage inverter. Supply voltage 3AC 525-690 V. Power 160 kw. Output current 550 v 201 A, 690 v 192 A. Frame size D3. IP 0
VLT HVAC Drive FC102. Low-voltage inverter. Supply voltage 3AC 525-690 V. Power 200 kw. Output current 550 v 253 A, 690 v 242 A. Frame size D4. IP 0
VLT HVAC Drive FC102. Low-voltage inverter. Supply voltage 3AC 525-690 V. Power 250 kw. Output current 550 v 303 A, 690 v 290 A. Frame size D4. IP 0
VLT HVAC Drive FC102. Low-voltage inverter. Supply voltage 3AC 525-690 V. Power 315 kw. Output current 550 v 360 A, 690 v 344 A. Frame size D4. IP 0
VLT HVAC Drive FC102. Low-voltage inverter. Supply voltage 3AC 525-690 V. Power 400 kw. Output current 550 v 418 A, 690 v 400 A. Frame size D4. IP 0
VLT HVAC Drive FC102. Low-voltage inverter. Supply voltage 3AC 525-690 V. Power 450 kw. Output current 550 v 470 A, 690 v 450 A. Frame size E2. IP 0
VLT HVAC Drive FC102. Low-voltage inverter. Supply voltage 3AC 525-690 V. Power 500 kw. Output current 550 v 523 A, 690 v 500 A. Frame size E2. IP 0
VLT HVAC Drive FC102. Low-voltage inverter. Supply voltage 3AC 525-690 V. Power 560 kw. Output current 550 v 596 A, 690 v 570 A. Frame size E2. IP 0
VLT HVAC Drive FC102. Low-voltage inverter. Supply voltage 3AC 525-690 V. Power 630 kw. Output current 550 v 630 A, 690 v 630 A. Frame size E2. IP 0
VLT HVAC Drive FC102. Low-voltage inverter. Supply voltage 3AC 525-690 V. Power 45 kw. Output current 550 v 56 A, 690 v 54 A. Frame size D1. IP 21
VLT HVAC Drive FC102. Low-voltage inverter. Supply voltage 3AC 525-690 V. Power 55 kw. Output current 550 v 76 A, 690 v 73 A. Frame size D1. IP 21
VLT HVAC Drive FC102. Low-voltage inverter. Supply voltage 3AC 525-690 V. Power 75 kw. Output current 550 v 90 A, 690 v 86 A. Frame size D1. IP 21
VLT HVAC Drive FC102. Low-voltage inverter. Supply voltage 3AC 525-690 V. Power 90 kw. Output current 550 v 113 A, 690 v 108 A. Frame size D1. IP 21
VLT HVAC Drive FC102. Low-voltage inverter. Supply voltage 3AC 525-690 V. Power 110 kw. Output current 550 v 137 A, 690 v 131 A. Frame size D1. IP 21
VLT HVAC Drive FC102. Low-voltage inverter. Supply voltage 3AC 525-690 V. Power 132 kw. Output current 550 v 162 A, 690 v 155 A. Frame size D1. IP 21
VLT HVAC Drive FC102. Low-voltage inverter. Supply voltage 3AC 525-690 V. Power 160 kw. Output current 550 v 201 A, 690 v 192 A. Frame size D1. IP 21
VLT HVAC Drive FC102. Low-voltage inverter. Supply voltage 3AC 525-690 V. Power 200 kw. Output current 550 v 253 A, 690 v 242 A. Frame size D2. IP 21
VLT HVAC Drive FC102. Low-voltage inverter. Supply voltage 3AC 525-690 V. Power 250 kw. Output current 550 v 303 A, 690 v 290 A. Frame size D2. IP 21
VLT HVAC Drive FC102. Low-voltage inverter. Supply voltage 3AC 525-690 V. Power 315 kw. Output current 550 v 360 A, 690 v 344 A. Frame size D2. IP 21
VLT HVAC Drive FC102. Low-voltage inverter. Supply voltage 3AC 525-690 V. Power 400 kw. Output current 550 v 418 A, 690 v 400 A. Frame size D2. IP 21
VLT HVAC Drive FC102. Low-voltage inverter. Supply voltage 3AC 525-690 V. Power 450 kw. Output current 550 v 470 A, 690 v 450 A. Frame size E1. IP 21
VLT HVAC Drive FC102. Low-voltage inverter. Supply voltage 3AC 525-690 V. Power 500 kw. Output current 550 v 523 A, 690 v 500 A. Frame size E1. IP 21
VLT HVAC Drive FC102. Low-voltage inverter. Supply voltage 3AC 525-690 V. Power 560 kw. Output current 550 v 596 A, 690 v 570 A. Frame size E1. IP 21
VLT HVAC Drive FC102. Low-voltage inverter. Supply voltage 3AC 525-690 V. Power 630 kw. Output current 550 v 630 A, 690 v 630 A. Frame size E1. IP 21
VLT HVAC Drive FC102. Low-voltage inverter. Supply voltage 3AC 525-690 V. Power 710 kw. Output current 550 v 763 A, 690 v 730 A. Frame size F1/F3. IP 21
VLT HVAC Drive FC102. Low-voltage inverter. Supply voltage 3AC 525-690 V. Power 800 kw. Output current 550 v 889 A, 690 v 850 A. Frame size F1/F3. IP 21
VLT HVAC Drive FC102. Low-voltage inverter. Supply voltage 3AC 525-690 V. Power 900 kw. Output current 550 v 988 A, 690 v 945 A. Frame size F1/F3. IP 21
VLT HVAC Drive FC102. Low-voltage inverter. Supply voltage 3AC 525-690 V. Power 1000 kw. Output current 550 v 1108 A, 690 v 1060 A. Frame size F2/F4. IP 21
VLT HVAC Drive FC102. Low-voltage inverter. Supply voltage 3AC 525-690 V. Power 1200 kw. Output current 550 v 1317 A, 690 v 1260 A. Frame size F2/F4. IP 21
VLT HVAC Drive FC102. Low-voltage inverter. Supply voltage 3AC 525-690 V. Power 1400 kw. Output current 550 v 1479 A, 690 v 1415 A. Frame size F2/F4. IP 21
VLT HVAC Drive FC102. Low-voltage inverter. Supply voltage 3AC 525-690 V. Power 45 kw. Output current 550 v 56 A, 690 v 54 A. Frame size D1. IP 54
VLT HVAC Drive FC102. Low-voltage inverter. Supply voltage 3AC 525-690 V. Power 55 kw. Output current 550 v 76 A, 690 v 73 A. Frame size D1. IP 54
VLT HVAC Drive FC102. Low-voltage inverter. Supply voltage 3AC 525-690 V. Power 75 kw. Output current 550 v 90 A, 690 v 86 A. Frame size D1. IP 54
VLT HVAC Drive FC102. Low-voltage inverter. Supply voltage 3AC 525-690 V. Power 90 kw. Output current 550 v 113 A, 690 v 108 A. Frame size D1. IP 54
VLT HVAC Drive FC102. Low-voltage inverter. Supply voltage 3AC 525-690 V. Power 110 kw. Output current 550 v 137 A, 690 v 131 A. Frame size D1. IP 54
VLT HVAC Drive FC102. Low-voltage inverter. Supply voltage 3AC 525-690 V. Power 132 kw. Output current 550 v 162 A, 690 v 155 A. Frame size D1. IP 54
VLT HVAC Drive FC102. Low-voltage inverter. Supply voltage 3AC 525-690 V. Power 160 kw. Output current 550 v 201 A, 690 v 192 A. Frame size D1. IP 54
VLT HVAC Drive FC102. Low-voltage inverter. Supply voltage 3AC 525-690 V. Power 200 kw. Output current 550 v 253 A, 690 v 242 A. Frame size D2. IP 54
VLT HVAC Drive FC102. Low-voltage inverter. Supply voltage 3AC 525-690 V. Power 250 kw. Output current 550 v 303 A, 690 v 290 A. Frame size D2. IP 54
VLT HVAC Drive FC102. Low-voltage inverter. Supply voltage 3AC 525-690 V. Power 315 kw. Output current 550 v 360 A, 690 v 344 A. Frame size D2. IP 54
VLT HVAC Drive FC102. Low-voltage inverter. Supply voltage 3AC 525-690 V. Power 400 kw. Output current 550 v 418 A, 690 v 400 A. Frame size D2. IP 54
VLT HVAC Drive FC102. Low-voltage inverter. Supply voltage 3AC 525-690 V. Power 450 kw. Output current 550 v 470 A, 690 v 450 A. Frame size E1. IP 54
VLT HVAC Drive FC102. Low-voltage inverter. Supply voltage 3AC 525-690 V. Power 500 kw. Output current 550 v 523 A, 690 v 500 A. Frame size E1. IP 54
VLT HVAC Drive FC102. Low-voltage inverter. Supply voltage 3AC 525-690 V. Power 560 kw. Output current 550 v 596 A, 690 v 570 A. Frame size E1. IP 54
VLT HVAC Drive FC102. Low-voltage inverter. Supply voltage 3AC 525-690 V. Power 630 kw. Output current 550 v 630 A, 690 v 630 A. Frame size E1. IP 54
VLT HVAC Drive FC102. Low-voltage inverter. Supply voltage 3AC 525-690 V. Power 710 kw. Output current 550 v 763 A, 690 v 730 A. Frame size F1/F3. IP 54
VLT HVAC Drive FC102. Low-voltage inverter. Supply voltage 3AC 525-690 V. Power 800 kw. Output current 550 v 889 A, 690 v 850 A. Frame size F1/F3. IP 54
VLT HVAC Drive FC102. Low-voltage inverter. Supply voltage 3AC 525-690 V. Power 900 kw. Output current 550 v 988 A, 690 v 945 A. Frame size F1/F3. IP 54
VLT HVAC Drive FC102. Low-voltage inverter. Supply voltage 3AC 525-690 V. Power 1000 kw. Output current 550 v 1108 A, 690 v 1060 A. Frame size F2/F4. IP 54
VLT HVAC Drive FC102. Low-voltage inverter. Supply voltage 3AC 525-690 V. Power 1200 kw. Output current 550 v 1317 A, 690 v 1260 A. Frame size F2/F4. IP 54
VLT HVAC Drive FC102. Low-voltage inverter. Supply voltage 3AC 525-690 V. Power 1400 kw. Output current 550 v 1479 A, 690 v 1415 A. Frame size F2/F4. IP 54
VLT HVAC Drive FC102. Low-voltage inverter. Supply voltage 3AC 525-690 V. Power 45 kw. Output current 550 v 56 A, 690 v 54 A. Frame size D1. IP 55
VLT HVAC Drive FC102. Low-voltage inverter. Supply voltage 3AC 525-690 V. Power 55 kw. Output current 550 v 76 A, 690 v 73 A. Frame size D1. IP 55
VLT HVAC Drive FC102. Low-voltage inverter. Supply voltage 3AC 525-690 V. Power 75 kw. Output current 550 v 90 A, 690 v 86 A. Frame size D1. IP 55
VLT HVAC Drive FC102. Low-voltage inverter. Supply voltage 3AC 525-690 V. Power 90 kw. Output current 550 v 113 A, 690 v 108 A. Frame size D1. IP 55
VLT HVAC Drive FC102. Low-voltage inverter. Supply voltage 3AC 525-690 V. Power 110 kw. Output current 550 v 137 A, 690 v 131 A. Frame size D1. IP 55
VLT HVAC Drive FC102. Low-voltage inverter. Supply voltage 3AC 525-690 V. Power 132 kw. Output current 550 v 162 A, 690 v 155 A. Frame size D1. IP 55
VLT HVAC Drive FC102. Low-voltage inverter. Supply voltage 3AC 525-690 V. Power 160 kw. Output current 550 v 201 A, 690 v 192 A. Frame size D1. IP 55
VLT HVAC Drive FC102. Low-voltage inverter. Supply voltage 3AC 525-690 V. Power 200 kw. Output current 550 v 253 A, 690 v 242 A. Frame size D2. IP 55
VLT HVAC Drive FC102. Low-voltage inverter. Supply voltage 3AC 525-690 V. Power 250 kw. Output current 550 v 303 A, 690 v 290 A. Frame size D2. IP 55
VLT HVAC Drive FC102. Low-voltage inverter. Supply voltage 3AC 525-690 V. Power 315 kw. Output current 550 v 360 A, 690 v 344 A. Frame size D2. IP 55
VLT HVAC Drive FC102. Low-voltage inverter. Supply voltage 3AC 525-690 V. Power 400 kw. Output current 550 v 418 A, 690 v 400 A. Frame size D2. IP 55
VLT HVAC Drive FC102. Low-voltage inverter. Supply voltage 3AC 525-690 V. Power 450 kw. Output current 550 v 470 A, 690 v 450 A. Frame size E1. IP 55
VLT HVAC Drive FC102. Low-voltage inverter. Supply voltage 3AC 525-690 V. Power 500 kw. Output current 550 v 523 A, 690 v 500 A. Frame size E1. IP 55
VLT HVAC Drive FC102. Low-voltage inverter. Supply voltage 3AC 525-690 V. Power 560 kw. Output current 550 v 596 A, 690 v 570 A. Frame size E1. IP 55
VLT HVAC Drive FC102. Low-voltage inverter. Supply voltage 3AC 525-690 V. Power 630 kw. Output current 550 v 630 A, 690 v 630 A. Frame size E1. IP 55
VLT HVAC Drive FC102. Low-voltage inverter. Supply voltage 3AC 525-690 V. Power 710 kw. Output current 550 v 763 A, 690 v 730 A. Frame size F1/F3. IP 55
VLT HVAC Drive FC102. Low-voltage inverter. Supply voltage 3AC 525-690 V. Power 800 kw. Output current 550 v 889 A, 690 v 850 A. Frame size F1/F3. IP 55
VLT HVAC Drive FC102. Low-voltage inverter. Supply voltage 3AC 525-690 V. Power 900 kw. Output current 550 v 988 A, 690 v 945 A. Frame size F1/F3. IP 55
VLT HVAC Drive FC102. Low-voltage inverter. Supply voltage 3AC 525-690 V. Power 1000 kw. Output current 550 v 1108 A, 690 v 1060 A. Frame size F2/F4. IP 55
VLT HVAC Drive FC102. Low-voltage inverter. Supply voltage 3AC 525-690 V. Power 1200 kw. Output current 550 v 1317 A, 690 v 1260 A. Frame size F2/F4. IP 55
VLT HVAC Drive FC102. Low-voltage inverter. Supply voltage 3AC 525-690 V. Power 1400 kw. Output current 550 v 1479 A, 690 v 1415 A. Frame size F2/F4. IP 55
Ingetool Systems, SL don't assume any responsibility for the possible inaccuracy of any data contained within this site, but it is our constant endeavor to keep free of errors.
INGETOOL-SISTEMAS develops this platform to include the products and tools you wish.
Please, contact us.
INGETOOL-SISTEMAS, S.L.
Parque Empresarial Torneo
C/ Arquitectura 1, Torre 6, Pt. 8, Mod. 4
41015 Sevilla - Spain
Phone +34 95 431 13 91
Contact: info@multiselector.com
Copyright 2011-2015
New Drive-SelectionTool
X
From now, all the information most complete and updated in..
All the converters and its components, accessories, protections, contactors, cables, cabinets, etc...